Obľúbené: Dáta aktualizované: 25. novembra 2026

Kategórie

Internet1 425
Komunikácia330
Audio a video941
Grafika a dizajn570
Kancelária a produktivita1 192
Vývoj3 303
Umelá inteligencia614
Zabezpečenie410
Systémové nástroje3 210
Hry545
Vzdelávanie a veda242
Sieť a IT296

Argyll CMS 3.4.0 na stiahnutie

An ICC compatible color management system

Graeme Gill Správa systémov #16 Správa systémov
Toto je staršia verzia. Najnovšia verzia je 3.5.0. Argyll CMS 3.5.0 · Dátum vydania:

Inštalačné súbory 3.4.0

ArchitektúraTypPre kohoVeľkosť súboruStiahnuťSHA256
64-bit ZIP → Prenosná verzia — 38,0 MB argyllcms.com VirusTotal
32-bit ZIP → Prenosná verzia — 40,6 MB argyllcms.com VirusTotal

Odkaz a SHA256 pochádzajú z komunitného manifestu Windows Package Managera. Pred spustením porovnajte hash stiahnutého súboru.

Zoznam zmien

- Added support for Spyder and SpyderPRO (2024)
- Renamed proposed CIE 2012 2 and 10 degree to standard CIE 2015 2 and 10 degree observers, as per CIE 170-2:2015.
- Added -Y c: option to colprof and invprofcheck to allow setting/overriding alibration curves for setting final ink limits.
- Added -Y c: option to xicclu to allow setting/overriding calibration curves for setting final ink limits, and added -T flag to show ink limits.
- Fixed Spyder X and X2 to not make Device Disconect noise (if such sounds are enabled) on MSWin.
- Fixed bug in colprof -nI failing for CMYK profiles.
- Enhanced strip reader patch recognition to reject strips that don't start and end on the media, as well as adding some speed compensation to the patch recognition for non-zerbra ruler measurements.
- Fixed bug in i1Pro3 strip reading where it would return bad values if the zerbra stripe wasn't used.
- Changed chartread so that it will issue warnings of possible bad row or patch reading even when .ti2 reference measurement is not accurate (i.e. no preconditioning profile used in targen.)
- Increased emphasis of making sure that there is contrast between patches at the end of rows in printtarg patch ordering for strip instruments.
- Added -C parameter to targen to allow overriding any calibration curves found in the ICC profile, used to estimage the total ink limit from that in the ICC profile. Also better enforces final raw computes ink limits.
- Modified ccxxmake so that it checks that it has actually found a white seeming patch to use as the L*a*b* white reference, and the patch to de-weight. If there is no white patch (i.e. just RGB patches) then it will use D65 as the L*a*b* conversion reference. ccxxmake will fail if there are less than 3 patches.
- Fixed ICC profile writing so that it clips rather than failing when writing a ColorantTable PCS value that is out of range. A warning to stderr will be issued.
- Changed ColorMunki driver so that it is more forgiving about unexpected version string lengths.
- Fixed dispcal and dispread so that they won't error out if there is no instrument but the -M parameter is provided.

https://www.argyllcms.com/doc/ChangesSummary.html

Najobľúbenejšie v kategórii „Správa systémov“

Zobraziť všetko
  1. Salt MinionSpráva systémov · SaltStack, Inc
  2. GLPI AgentSpráva systémov · Teclib'
  3. MeshCommanderSpráva systémov · Ylianst
  4. EPA SWMM 5.2.4 (64-bit)Správa systémov · US EPA
  5. CMTrace OpenSpráva systémov · Adam Gell
  6. PDQ InventorySpráva systémov · PDQ.com
  7. Argyll CMSSpráva systémov · Graeme Gill
  8. DISMTools PreviewSpráva systémov · CodingWonders Software
  9. WSL DashboardSpráva systémov
  10. Intune WSL PluginSpráva systémov · Microsoft Corporation

Štítky

Zdieľať