Aquí hi ha 3 versions de PVSOL 2025, des de 20 de febrer del 2025 fins a l’actual, 2025.10. Cadascuna enllaça amb els instal·ladors del mateix desenvolupador.
| Versió | Data | Mida | Fitxers |
|---|---|---|---|
| 2025.10Darrera versió | 13 d’octubre del 2025 | 482,0 MB | 64 bits EXE (Inno Setup) 482,0 MB Notes de la versióThe following new features and changes are included:
- Calculation of annual cash flow in combination with taxes and loans revised.
- If a loan is used in the financial analysis, the results now also include the “Accrued Cash Flow (Cash Balance) minus pending loans” diagram.
- The “Energy cost trend” diagram can now be selected or deselected for the project report.
- The climate data from PVGIS has been updated to SARAH3.
- Revised calculation of direct own use of PV energy for DC intermediate circuit-coupled battery systems with time-controlled charging from the grid.
- When planning with a DC intermediate circuit-coupled battery system with time-controlled charging and the energy at the inverter input is less than the charge of the DC storage, the Sankey diagram is no longer displayed in the results. This can occur if the DC storage is also charged from the grid.
The following bugs have been fixed:
- Financial Analysis:
- In some cases, a heat pump was included in the calculation of savings, even though the system type did not include a heat pump.
- In some cases, the charging of the electric car from the battery was not taken into account in the calculation of savings.
- Error when loading the already simulated feed-in tariff in the first year when using DC battery systems and the Solar Peak Act calculation.
- Off-grid systems:
- Error when opening project files.
- When the simulation is aborted, only a simple message is displayed instead of the crash window.
- Crash when opening the Results page if a project from the previous version is loaded in which the simulation results were saved.
- Error in the display of data series from thermal systems when exporting to a *.csv file. |
| 2025.8 | 4 d’agost del 2025 | — | 64 bits EXE (Inno Setup) Notes de la versióThe following new features and changes are included:
- German “Solarspitzengesetz” (Solar Peak Act) can now be mapped in the economic efficiency.
- Revised cashflow table:
- Year 1 is now a full year.
- The last year may only be part of a year.
- The period of each year shown is listed.
- Display of the amortization period is no longer limited to the observation period.
- Photo Plan: Re-implementation of Braas roof tiles, Velux roof windows and measuring tools.
- In the circuit diagram, the DC intermediate-coupled battery systems are now drawn on the DC side of hybrid inverters.
- MeteoSyn: In case of errors during the import of climate data, the possible error is now indicated.
- In the simulation with a thermal system, the maximum value for hot water consumption was increased to 1,000,000 kWh.
- Improvement of the translation.
- New offline database.
The following bugs have been fixed:
- Crash in the simulation if the inverter characteristic curve only showed a value of over 0 % at a utilization rate of 10 %.
- Charging the e-vehicle from the battery system was not shown in the coverage of total consumption diagram.
- Licence management issue with error 401.
- Error in the login dialog of the license management:
- Login dialog did not respond.
- Login dialog did not display any content.
- Energy flow diagram:
- Display of energy flows from battery to electric car corrected.
- Error in balancing when using heating element.
- Error when saving the project files if characteristic curves should also be saved.
- Crash in the assignment of DC charge controller and inverter connections when using more than 10 DC battery systems.
- Crash in the characteristic curves if there was no PV yield in individual months.
- Partial crashes of the minute value synthesis at Brazilian locations.
- Photo Plan: Help could not be accessed with F1.
- Diagram PV energy during observation period did not show the correct observation period for projects located outside Germany.
- Partial problems with the diagrams for the economic calculation.
- User profiles: The tooltips were “hard coded”.
- The parameters "Year", "Month" and "Day" sometimes described a DateTime that could not be displayed.
- Automatic configuration search sometimes did not deliver any results for the SMA Tripower Core 2.
- The power specification of the backup generator was incorrect in the circuit diagram.
- Crash on the inverter window if the power optimizer field was clicked first and then the inverter model field immediately afterwards.
- Problems when entering degrees, minutes and seconds of coordinates in the map tool search. |
| 2025.3 | 20 de febrer del 2025 | — | 64 bits EXE (Inno Setup) Notes de la versióThe following new features and changes are included:
- Buttons for copying results tables and diagrams.
- Copy & Paste in the parts list now only copies the selected cells.
- Specific CO2 emissions are set to 380 g/kWh.
- Currents and voltages are now grouped during CSV export.
- Guernsey and Jersey added to MeteoSyn country list.
The following bugs have been fixed:
- Error when averaging 10- and 15-minute values in *.csv export.
- Crash when starting different PV*SOL variants and versions at the same time.
- Crash when exiting the financial analysis parameter dialog if the term and repayment free initial period year were set to the same value.
- Crash when simulating with bifacial modules and row spacing 0 m.
- Opening the options for *.csv export did not force a new simulation when changing the time step.
- Simulation progress dialog could no longer be closed with "Alt+F4".
- Error in checking the charging power for electric vehicles.
- Carpet plots in the project report are now prevented if simulation results are not available.
- Rare crash in calculation of DC power of DC-coupled battery systems.
- In some cases, the initialization file for the license management could not be deserialized.
- Error when using tracker systems for locations in the southern hemisphere.
- Display of the PV modules page in French, Spanish, Portuguese and Italian partially incorrect.
- Changing the country of the climate data led to the deletion of the financial analysis data for off-grid systems.
- The energy balance entries for power optimizers were not correctly labelled during *.csv export.
- Crash when defining a new PV module if the current or voltage in the MPP was higher than the short-circuit current or open-circuit voltage.
- Incorrect interpolation of power optimizer curves between negative and positive power consumption.
- Crash when starting PV*SOL due to IPC timing problem.
- When using battery systems with batteries based on lithium nickel manganese oxide, negative losses could occur in the battery.
- Main window no longer disappears into the background when MeteoSyn is called up.
- Simulation of time-controlled charging for DC-coupled battery systems was not possible.
- Error in the system check with Huawei optimizers.
- New license management:
- Crash when starting PV*SOL (UUID not available on some computers).
- Crash if the license file could not be written. |